Altinex PE1005 Betriebsanweisung

Stöbern Sie online oder laden Sie Betriebsanweisung nach Nein Altinex PE1005 herunter. Altinex PE1005 User`s guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 29
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
SPECIAL APPLICATION
MANUAL PART NUMBER: 400-0384-002
PE1005
CONTROL CARD FOR
PIONEER PLASMA DISPLAY
USER’S GUIDE
Seitenansicht 0
1 2 3 4 5 6 ... 28 29

Inhaltsverzeichnis

Seite 1 - USER’S GUIDE

SPECIAL APPLICATIONMANUAL PART NUMBER: 400-0384-002 PE1005CONTROL CARD FORPIONEER PLASMA DISPLAYUSER’S GUIDE

Seite 2

SPECIAL APPLICATION400-0384-00296. Click on the “Search” button to check for new devices on the LAN. NOTE: If you want to assign the IP manually, clic

Seite 3

SPECIAL APPLICATION400-0384-00210OPERATION 77.1 RS-232 CONTROL The PE1005 has many advanced remote control capabilities, which are accessible through

Seite 4

SPECIAL APPLICATION400-0384-00211Example:Reset the PE1005 with unit ID 1 to its default settings by sending the command [FRESETC1].The card will displ

Seite 5

SPECIAL APPLICATION400-0384-002127. [RDRL]This command is used to read the status of one or all of the internal relays. A ‘1’ indicates the relay is

Seite 6

SPECIAL APPLICATION400-0384-00213Example:Subroutine 10 is assigned to Input #1, subroutine 20 is assigned to Input #2, subroutine 30 is assigned to In

Seite 7

SPECIAL APPLICATION400-0384-0021415. [RDLS]This command displays the subroutine label of one or all subroutine memory locations.Command Format: [RDLS

Seite 8

SPECIAL APPLICATION400-0384-00215[SETTIME073000] [RDTIME]The display will be similar to the following:TIME: 07:30:0521. [SETDAY]This command is used

Seite 9

SPECIAL APPLICATION400-0384-00216Mode 1 = Every Minute Mode 2 = Every HourMode 3 = Every DayMode 4 = Every MonthMode 5 = Every WeekThe following is re

Seite 10 - SPECIAL APPLICATION

SPECIAL APPLICATION400-0384-00217Example:Associate Alarm #1 with subroutine 10 and set Alarm #1 to trigger at 12 noon every day by sending the followi

Seite 11

SPECIAL APPLICATION400-0384-00218The alarm functions that follow are used to setupthe alarms and enable and disable the alarms. The examples used in t

Seite 12

SPECIAL APPLICATION400-0384-0021TABLE OF CONTENTSPagePRECAUTIONS / SAFETY WARNINGS ... 2GENERAL...

Seite 13

SPECIAL APPLICATION400-0384-00219Example:Associate Alarm #2 with subroutine 10 and set Alarm #2 to trigger at 2:30PM on the 15thday of the month by se

Seite 14

SPECIAL APPLICATION400-0384-0022039. [ALRMn=SUBk]This command sets the dependencies between an alarm and a subroutine. The functions in the subroutin

Seite 15

SPECIAL APPLICATION400-0384-0022143. [RDLM]This command displays the data for one or all memory location labels.Command Format: [RDLMmCi]m = Memory L

Seite 16

SPECIAL APPLICATION400-0384-0022248. [OUTRSM]This command sends the contents of an RS memory location to the external RS-232 port.Command Format: [OU

Seite 17

SPECIAL APPLICATION400-0384-0022354. [SENDPS]This command sends data directly through the internal RS-232 bus to the main control card. The data

Seite 18

SPECIAL APPLICATION400-0384-00224Command Format: [SETMD=xCi]x = Trigger Level (x = # from 01 to 50)01 = 0.1V02 = 0.2V…50 = 5.0VCi = Unit ID (i = # fro

Seite 19

SPECIAL APPLICATION400-0384-00225REMEMBER: A command sent without the unit ID will be executed by all the PE1005’s connected to the RS-232 port.65. [

Seite 20

SPECIAL APPLICATION400-0384-0022636) [ALRMON] Activate Alarm.37) [ALRMOFF] Deactivate Alarm.38) [RDALRM] Read alarm settings.39) [ALRMn=SUBk] Set Alar

Seite 21

SPECIAL APPLICATION400-0384-00227Example 1: Adjustment ModePlace the plasma into adjustment mode by sending the following command directly to the int

Seite 22

SPECIAL APPLICATION400-0384-002288.3 INPUT PORTS DO NOT RESPONDCause 1: The input pin is not grounded.Solution: Short the input port to ground using

Seite 23

SPECIAL APPLICATION400-0384-0022PRECAUTIONS / SAFETY WARNINGS 1Please read this manual carefully before using your PE1005. Keep this manual handy for

Seite 24

SPECIAL APPLICATION400-0384-0023ABOUT YOUR PE1005 2PE1005PIONEER CONTROL CARDThe PE1005 Pioneer card allows users to control events on Pioneer Plasma

Seite 25

SPECIAL APPLICATION400-0384-0024DESCRIPTION OF PE1005 4APPLICATION DIAGRAMS 5DIAGRAM 1: TYPICAL SETUPCONNECTORRJ-45 NETWORK JACKCONNECTORTCP/IPDIGITAL

Seite 26

SPECIAL APPLICATION400-0384-0025DIAGRAM 2: INTERNAL VIEWETHERNET RJ-45USBTX/RXRC-232RS485TX/RXTXTXTXTXTXTXTX PDPRX PDPRX VIDEO CARDTX VIDEO CARDEDGE C

Seite 27

SPECIAL APPLICATION400-0384-0026DIAGRAM 3: CARD DETAILSLED1BATTERY3V LithiumCR1225P3Test ConnectorUsed for circuit card evaluation.SW1RS-232/RS-485 se

Seite 28

SPECIAL APPLICATION400-0384-0027DIAGRAM 4: 25 PIN HD DETAILSDIAGRAM 5: MOTION DETECTOR DETAILSRANGEMINMAXGAINSCALEN/CANALOG OUTPWM CLOCK OUTTRIG.. ENA

Seite 29

SPECIAL APPLICATION400-0384-0028INSTALLING YOUR PE1005 6Step 1. Turn off the power to the plasma display. Step 2. Use ESD safety precautions and alway

Kommentare zu diesen Handbüchern

Keine Kommentare