MULTI-TASKER
8
Ui = Unit ID (i = # from 0 to 9) (refer to the
MT100-100 user’s guide for explanation)
Example:
If one Scan Doubler Card is in slot #2 of unit 3.
Send the command [VERC2U3], and the
Multi-Tasker™ Basic Enclosure will return the
following:
MT106-101 690-0155-003
MT106-101 = card type
690-0155-003 = software version
2. [C]
This command receives the status of the card.
Command Format: [CnUi]
Cn = card ID (n = a slot # from 1 to 19)
(1-8 for MT100-101 or 1-4 for MT100-106)
Ui = unit id (i = 0 to 9) (refer to the MT100-100
user’s guide for explanation)
Example:
If there is one MT106-101 card in slot #2 of unit
3 set for NTSC outputs, sending the command
[C2U3] to the Multi-Tasker™ will yield the
following feedback:
INPUT: 640x480; OUTPUT: NTSC C02
INPUT: 640x480 = Input resolution
OUTPUT: NTSC = Output mode
C02 = card is in slot 2
If there is no card in slot #2 of unit 3, sending
the [C2U3] command will not return any
feedback from either card.
3. [SIGCi]
The Signal Present command tests for the
presence of a signal on the input. After sending
the command, the feedback will be either "1"
signifying a signal is present, or "0" indicating no
signal was detected.
Ci = card number
Example:
To check for the presence of an input signal on
card 4, send the command [SIGC4] and verify
feedback of "1" or "0".
4. [CLR]
This command resets the card configuration to
factory defaults.
Command Format: [CLRCi]
Ci = card ID (n = a slot # from 1 to 19)
(1-8 for MT100-101 or 1-4 for MT100-106)
Example:
There is an MT106-101 in slot 4 of unit 0. All
controls are set to various levels and the output
is in PAL mode. Sending the command
[CLRC4] will set the level controls to their
default values and place the output in NTSC
format.
5. [ON]
The ON command selects one of four possible
input sources to connect to the output.
INPUT Number
( n )
INPUT Signal
Name
0 S-Video
1 C-Video #1
2 C-Video #2
3 C-Video #3
Command Format: [ONnCiUy]
n = value from 0 to 3
Ci = card ID (i = slot number)
Uy = unit id (i = 0 to 9) (refer to the MT100-100
user’s guide for explanation)
Example:
Connect the S-Video signal input on the
MT106-101 located in slot 4 of unit ID 2 to the
VGA output connector.
[ON0C4U2]
6. [ + ] or [ - ]
These commands allow the user to increase or
decrease the value of the selected attribute.
They must be used immediately following one of
the following STATUS commands.
Kommentare zu diesen Handbüchern